TECHNICAL DATA
Explosion protection according to EN LCIE (Laboratoire Central des Industries Electriques)
Conformity certificate LCIE 01 ATEX 6073 X / 06, IECEx LCI 07.0020X
Heating element high performance cartridge
Heater body aluminium profile, silver anodised
Connection Si HF-JZ 3 x 0.75mm2 cable, length 1m
Connection PE 4mm2
Mounting clip for 35mm DIN rail, EN 60715
Fitting position vertical airflow (connection on bottom)
Storage temperature -45 to +70°C (-49 to +158°F)
Protection type/Protection class IP65 / I (earthed)
Approvals EAC submitted
Art.
No. Operating voltage Heating capacity Pre-fuse T (time-delay) Ambient
temperature1 Ex protection type
Ex II 2 GD
Gases Dusts Surface
temperature Length (L) Weight (approx.)
02010.0-00 230-240VAC 50W 0.5A -40 to +50°C (-40 to +122°F) Ex d IIC T5 Gb Ex tb IIIC T100°C Db IP6X T5 = +100°C (+212°F) 150mm 1.3kg
-40 to +85°C (-40 to +185°F) Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP6X T4 = +135°C (+275°F)
02010.0-01 110-120VAC 50W 1A -40 to +50°C (-40 to +122°F) Ex d IIC T5 Gb Ex tb IIIC T100°C Db IP6X T5 = +100°C (+212°F) 150mm 1.3kg
-40 to +85°C (-40 to +185°F) Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP6X T4 = +135°C (+275°F)
02011.0-00 230-240VAC 100W 1A -40 to +50°C (-40 to +122°F) Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP6X T4 = +135°C (+275°F) 180mm 1.5kg
-40 to +85°C (-40 to +185°F) Ex d IIC T3 Gb Ex tb IIIC T200°C Db IP6X T3 = +200°C (+392°F)
02011.0-01 110-120VAC 100W 2A -40 to +50°C (-40 to +122°F) Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP6X T4 = +135°C (+275°F) 180mm 1.5kg
-40 to +85°C (-40 to +185°F) Ex d IIC T3 Gb Ex tb IIIC T200°C Db IP6X T3 = +200°C (+392°F) |
 |
|